RTO Waste Gas Treatment Equipment
video
RTO Waste Gas Treatment Equipment

RTO Waste Gas Treatment Equipment

Equipment Size: 3000 × 2200 × 3500 mm
Airflow Volume: 8000 m³/h
Treatment Method: Regenerative Thermal Oxidation
Application Scenario: High-concentration VOC exhaust
Destruction Efficiency: ≥99%

High-Efficiency Destruction for Concentrated VOCs

 

For high-concentration VOC exhaust, activated carbon adsorption is not cost-effective. The activated carbon reaches saturation too quickly, and replacement costs can become very high. RTO (Regenerative Thermal Oxidizer) uses high-temperature thermal oxidation to treat these VOCs. The exhaust enters the combustion chamber and is oxidized at temperatures above 800°C. The VOC molecules are converted into carbon dioxide and water. The VOC destruction efficiency can exceed 99%.
The ceramic heat storage media inside the chamber act as a heat recovery system. They preheat incoming exhaust and recover heat from outgoing gas. The high heat recovery efficiency helps reduce overall operating energy costs. For high-concentration VOC applications, this RTO Waste Gas Treatment Equipment provides a reliable and efficient solution.

 

Two Sizes for Different Production Scales

 

The small model has dimensions of 3000 × 2200 × 3500 mm and provides an airflow capacity of 8000 m³/h. It is suitable for small to medium coating or chemical workshops. The large model has dimensions of 6000 × 3000 × 4500 mm and provides an airflow capacity of 30000 m³/h. It is designed for large-scale continuous production.
Our engineering team has experience in RTO system design and commissioning. We configure the appropriate number of heat storage chambers, switching valve cycles, and burner capacity according to your VOC concentration and airflow requirements. Before shipment, we inspect the heat storage media installation, test valve switching performance, and verify the temperature control system. Production takes 10 to 30 days, and we accept orders for a single unit.

 

Global Compliance and Support

 

We can customize the inlet/outlet direction and stack height according to your site conditions. Payment terms are 40% in advance and 60% before shipment. Third-party inspections are accepted.
Chemical and coating companies in Europe and Southeast Asia are already using our RTO equipment. They have achieved compliance with local emission standards. Our after-sales team provides guidance on operating parameter settings and regular maintenance. The equipment comes with a 12-month warranty.
If you need to treat high-concentration VOC exhaust while meeting strict standards, we can provide thermal efficiency calculations and return-on-investment (ROI) analysis for this RTO Waste Gas Treatment Equipment.

 

Specifications

 

Parameter

Small Model

Large Model

Equipment Size

3000 × 2200 × 3500 mm

6000 × 3000 × 4500 mm

Airflow Volume

8000 m³/h

30000 m³/h

Treatment Method

Regenerative Thermal Oxidation

Regenerative Thermal Oxidation

Application Scenario

High-concentration VOC exhaust

High-concentration VOC exhaust

Destruction Efficiency

≥99%

≥99%

 

Hot Tags: rto waste gas treatment equipment, China rto waste gas treatment equipment manufacturers, suppliers, factory